==Materials (Bring Downstairs)==
+
==SOP==
 +
*[[SOP - Needle Capping]]
 +
*[[Safety and Animal Training]]
 +
 
 +
 
 +
==Materials (Bring to Procedure Room)==
 
*Glucometer - AccuChek Advantage
 
*Glucometer - AccuChek Advantage
*Glucose Test Strips - AccuChek Comfort Curve
+
*Glucose Test Strips - AccuChek Comfort Curve.  Order these through Materiels Service by calling 936-6077 and ordering product 2535.  For information see [[https://www31.med.umich.edu/materielsvcs/catalog/details.cfm?stock=2535 here]]. collect in university hospital building, floor B2 in room B2F408 dock 5 across from central pharmacy.
 
*Scale
 
*Scale
 
*Beaker for weighing mice
 
*Beaker for weighing mice
 
*Syringes
 
*Syringes
 
*10% Glucose in PBS (make as 1g in 10 mL, sterile filtered).  This will correspond to 1g/kg glucose injections.
 
*10% Glucose in PBS (make as 1g in 10 mL, sterile filtered).  This will correspond to 1g/kg glucose injections.
 +
*If doing an oral glucose tolerance test need a gavage needle
 
*Timer
 
*Timer
  
Line 11: Line 17:
 
#Remove food from mice for about 6h.  Add do not feed tag to cages.
 
#Remove food from mice for about 6h.  Add do not feed tag to cages.
 
#Bring mice to procedure room. Put water bottle on cage.
 
#Bring mice to procedure room. Put water bottle on cage.
#Weigh mice, mark tails as necessary and take fasting glucose measurement.
+
#Weigh mice, mark tails as necessary and take fasting glucose measurement.  If necessary also take blood for [[Measuring Fasting Insulin]] by filling a heparinized capillary about 2/3 full with blood.
 
#Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
 
#Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
#At 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse.
+
#At 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse or the mouth if doing an oral glucose tolerance test.
:#Immobilize mouse and restrain tail with one hand
+
##Immobilize mouse and restrain tail with one hand
:#Aim needle between the midline and the hip bone
+
##'''For ipGTT''' Aim needle between the midline and the hip bone
:#Insert syringe (do not inject) into cavity
+
##'''For oGTT''' Gently inert gavage needle into mouth
:#Pull up syringe and ensure that only air is aspirated.  If urine or blood appears in the syringe, start over
+
##Insert syringe (do not inject) into cavity/mouth
:#Eject syringe.
+
##'''For ipGTT:''' Pull up the syringe and ensure that only air is aspirated.  If urine or blood appears in the syringe, start over
#At desired intervals (normally 15, 30, 45, 60, 75, 90 and 120 min), take blood glucose measurements from tail vein
+
##Eject syringe.
 +
#At desired intervals (normally 15, 30, 45, 60, 75, 90, and 120 min), take blood glucose measurements from the tail vein
 +
 
 +
[[Category:Mouse Work]]
 +
[[Category:Glucose Homeostasis]]
 +
[[Category:Injections]]

Latest revision as of 17:37, 28 March 2023

SOP


Materials (Bring to Procedure Room)

  • Glucometer - AccuChek Advantage
  • Glucose Test Strips - AccuChek Comfort Curve. Order these through Materiels Service by calling 936-6077 and ordering product 2535. For information see [here]. collect in university hospital building, floor B2 in room B2F408 dock 5 across from central pharmacy.
  • Scale
  • Beaker for weighing mice
  • Syringes
  • 10% Glucose in PBS (make as 1g in 10 mL, sterile filtered). This will correspond to 1g/kg glucose injections.
  • If doing an oral glucose tolerance test need a gavage needle
  • Timer

Protocol

  1. Remove food from mice for about 6h. Add do not feed tag to cages.
  2. Bring mice to procedure room. Put water bottle on cage.
  3. Weigh mice, mark tails as necessary and take fasting glucose measurement. If necessary also take blood for Measuring Fasting Insulin by filling a heparinized capillary about 2/3 full with blood.
  4. Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
  5. At 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse or the mouth if doing an oral glucose tolerance test.
    1. Immobilize mouse and restrain tail with one hand
    2. For ipGTT Aim needle between the midline and the hip bone
    3. For oGTT Gently inert gavage needle into mouth
    4. Insert syringe (do not inject) into cavity/mouth
    5. For ipGTT: Pull up the syringe and ensure that only air is aspirated. If urine or blood appears in the syringe, start over
    6. Eject syringe.
  6. At desired intervals (normally 15, 30, 45, 60, 75, 90, and 120 min), take blood glucose measurements from the tail vein