Difference between revisions of "Glucose Tolerance Test"

From Bridges Lab Protocols
Jump to: navigation, search
(Materials (Bring Downstairs))
(Protocol)
Line 18: Line 18:
 
:#Pull up syringe and ensure that only air is aspirated.  If urine or blood appears in the syringe, start over
 
:#Pull up syringe and ensure that only air is aspirated.  If urine or blood appears in the syringe, start over
 
:#Eject syringe.
 
:#Eject syringe.
 +
#At desired intervals (normally 15, 30, 45, 60, 75, 90 and 120 min), take blood glucose measurements from tail vein

Revision as of 15:42, 13 May 2009

Materials (Bring Downstairs)

  • Glucometer
  • Glucose Test Strips
  • Scale
  • Beaker for weighing mice
  • Syringes
  • 10% Glucose in PBS (make as 1g in 10 mL, sterile filtered). This will correspond to 1g/kg glucose injections.

Protocol

  1. Remove food from mice for about 6h. Add do not feed tag to cages.
  2. Bring mice to procedure room.
  3. Weigh mice, mark tails as necessary and take fasting glucose measurement.
  4. Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
  5. At 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse.
  1. Immobilize mouse and restrain tail with one hand
  2. Aim needle between the midline and the hip bone
  3. Insert syringe (do not inject) into cavity
  4. Pull up syringe and ensure that only air is aspirated. If urine or blood appears in the syringe, start over
  5. Eject syringe.
  1. At desired intervals (normally 15, 30, 45, 60, 75, 90 and 120 min), take blood glucose measurements from tail vein