Preparing an Agarose Gel
Materials
- Agarose
- TAE Buffer (1X): Dilute from 100X stock
- BioRad Gel Apparatus (Mold, Holder, Comb and Gel Rig)
Prepare Gel (BioRad Gel Rig)
- Place plastic mold in holder and turn handle to tighten
- Put 15 or 8 well comb in mold as appropriate
- Weight out 0.3g agarose and add 30 mL of TAE
- Microwave 40s until dissolved
- Add 1 uL ethidium bromide
- Pour into mold
- Place gel in cold room if in a hurry
- After loading, run gel at 100V and dispose in ethidium bromid waste