==Materials (Bring Downstairs)==
==SOP==
*[[SOP - Needle Capping]]
*[[Safety and Animal Training]]
 
 
==Materials (Bring to Procedure Room)==
*Glucometer - AccuChek Advantage
*Glucometer - AccuChek Advantage
*Glucose Test Strips - AccuChek Comfort Curve.  Order these through Materiels Service by calling 936-6077 and ordering product 2535.  For information see [[https://www31.med.umich.edu/materielsvcs/catalog/details.cfm?stock=2535 here]]
*Glucose Test Strips - AccuChek Comfort Curve.  Order these through Materiels Service by calling 936-6077 and ordering product 2535.  For information see [[https://www31.med.umich.edu/materielsvcs/catalog/details.cfm?stock=2535 here]]. collect in university hospital building, floor B2 in room B2F408 dock 5 across from central pharmacy.
*Scale
*Scale
*Beaker for weighing mice
*Beaker for weighing mice
*Syringes
*Syringes
*10% Glucose in PBS (make as 1g in 10 mL, sterile filtered).  This will correspond to 1g/kg glucose injections.
*10% Glucose in PBS (make as 1g in 10 mL, sterile filtered).  This will correspond to 1g/kg glucose injections.
*If doing an oral glucose tolerance test need a gavage needle
*Timer
*Timer


Line 11: Line 17:
#Remove food from mice for about 6h.  Add do not feed tag to cages.
#Remove food from mice for about 6h.  Add do not feed tag to cages.
#Bring mice to procedure room. Put water bottle on cage.
#Bring mice to procedure room. Put water bottle on cage.
#Weigh mice, mark tails as necessary and take fasting glucose measurement.  If necessary also take blood for [[Measuring Fasting Insulin]] by filling a heparinized capilary about 2/3 full with blood.
#Weigh mice, mark tails as necessary and take fasting glucose measurement.  If necessary also take blood for [[Measuring Fasting Insulin]] by filling a heparinized capillary about 2/3 full with blood.
#Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
#Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
#At 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse.
#At 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse or the mouth if doing an oral glucose tolerance test.
##Immobilize mouse and restrain tail with one hand
##Immobilize mouse and restrain tail with one hand
##Aim needle between the midline and the hip bone
##'''For ipGTT''' Aim needle between the midline and the hip bone
##Insert syringe (do not inject) into cavity
##'''For oGTT''' Gently inert gavage needle into mouth
##Pull up syringe and ensure that only air is aspirated.  If urine or blood appears in the syringe, start over
##Insert syringe (do not inject) into cavity/mouth
##'''For ipGTT:''' Pull up the syringe and ensure that only air is aspirated.  If urine or blood appears in the syringe, start over
##Eject syringe.
##Eject syringe.
#At desired intervals (normally 15, 30, 45, 60, 75, 90 and 120 min), take blood glucose measurements from tail vein
#At desired intervals (normally 15, 30, 45, 60, 75, 90, and 120 min), take blood glucose measurements from the tail vein


[[Category:Animal Work]]
[[Category:Mouse Work]]
[[Category:Mouse Work]]
[[Category:Glucose Homeostasis]]
[[Category:Glucose Homeostasis]]
[[Category:Injections]]
[[Category:Injections]]