Insulin Tolerance Test

Revision as of 15:00, 13 May 2011 by Davebridges (Talk | contribs) (updated with new starvation and added additional information)

Revision as of 15:00, 13 May 2011 by Davebridges (Talk | contribs) (updated with new starvation and added additional information)

Materials (Bring Downstairs)

  • Glucometer - AccuChek Advantage
  • Glucose Test Strips - AccuChek Comfort Curve. Order these through Materiels Service by calling 936-6077 and ordering product 2535. For information see [here]
  • Scale
  • Beaker for weighing mice
  • Syringes
  • 0.1 U/mL humulin in PBS (make as 10uL of 100 U/mL in 10 mL, sterile filtered). This will correspond to 1 U/kg injections. This may need to be adjusted depending on the insulin sensitivity of the mice
  • Timer

Protocol

  • Remove food from mice for about 6h. Add do not feed tag to cages, or move cage to procedure room.
  • Separate mice into individual cages and mark with mouse ID. Put a water bottle on the cage.
  • Typically starve the mice at 9AM and aim to start injections at 3 PM
  • Weigh mice, mark tails as necessary and take fasting glucose measurement via a tail clip.
  • Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
  • At approximately 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse.
  • Immobilize mouse and restrain tail with one hand
  • Aim needle between the midline and the hip bone
  • Insert syringe (do not inject) into cavity
  • Pull up syringe and ensure that only air is aspirated. If urine or blood appears in the syringe, start over
  • Eject syringe.
  • At desired intervals (normally 15, 30, 45, 60, 75, 90 and 120 min), take blood glucose measurements from tail vein
  • Analyse data by both % change from fasting glucose and absolute values