Difference between revisions of "Deparaffinizing Histology Slides"
From Bridges Lab Protocols
(created) |
(added SOP requirements) |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
− | Materials | + | ==SOP== |
+ | *[[SOP- Corrosives]] | ||
+ | *[[SOP- Irritants]] | ||
+ | *[[SOP- Flammables and Combustibles]] | ||
+ | |||
+ | ==Materials== | ||
#Xylene | #Xylene | ||
Line 10: | Line 15: | ||
#Xylene: 2 x 3 minutes | #Xylene: 2 x 3 minutes | ||
− | #Xylene 1: | + | #Xylene 1:1 with 100% Ethanol: 3 minutes |
#100% Ethanol: 2 x 3 minutes | #100% Ethanol: 2 x 3 minutes | ||
#95% Ethanol: 3 minutes | #95% Ethanol: 3 minutes |
Latest revision as of 21:52, 4 June 2020
SOP
Materials
- Xylene
- 100% Ethanol
- 95% Ethanol
Method
- Use slide rack/holder
- Xylene: 2 x 3 minutes
- Xylene 1:1 with 100% Ethanol: 3 minutes
- 100% Ethanol: 2 x 3 minutes
- 95% Ethanol: 3 minutes
- 70% Ethanol: 3 minutes
- 50% Ethanol: 3 minutes
- Running cold tap water to rinse
Keep the slides in the tap water until ready to perform staining protocol.